Ahalia Foundation   Eye Hospital
The hospital For patients Eye departments
Eye health facilities For patients
Ahalia Foundation Eye Hospital Ahalia Foundation Eye Hospital Ahalia Foundation Eye Hospital
Doctor profile






MAJOR EQUIPMENTS



Click to view enlarge
Baush & Lomb Lasik Laser Zyoptix Z100


Purpose :
Most advanced excimer laser treatment to correct refractive errors of eye


Specification : Customized wave front assisted correction of refractive errors. Z-100 laser, featuring iris recognition technology, multi dimensional eye tracker, 100 hz laser source giving greater precision and superior alignment between defect and correction.


...............................................................................................................


Click to view enlarge
Carl Zeiss operating microscope OPMI VISU 210


Purpose :
Anterior & posterior segment Micro surgery


Specification : Enhanced depth of field, resolution & contrast, xenon illumination for exceptional contrast true colour images, integrated stereoscopic assistance microscope, maximum light transmission, integrated slit illumination, ergonomic handgrips for precise positioning, fully apochromatically corrected optics, Deep View system.


...............................................................................................................


Click to view enlarge
Alcon Accurus vitrectomy System


Purpose :
Anterior and posterior vitrectomy surgeries


Specification : Multi functional surgical tool, graphic user interface for ease of operation, pulsed air pressure to drive vitreous cutter probe and scissors, halogen bulb for fibre optic illumination, posterior vitrectomy with four hand pieces, unique innovit probe fragmentation, diathermy (MPC), video Overlay.


...............................................................................................................



Click to view enlarge
Iridex Green laser (oculight GL)Solid state Green Laser Photo coagulator


Purpose :
Photocoagulation for various retinal diseases including diabetic retinopathy. Laser trabeculoplasty


Specification : Diode pumped frequency doubled, solid state laser, 532 nm (green), CW power on demand technology, compatible with laser indirect ophthalmoscope, slit lamp adaptors & endoprobes, portable & compact design.


...............................................................................................................


Click to view enlarge
Carl Zeiss visulas Yag III laser


Purpose :
Peripheral iridotomy & anterior capsulotomy


Specification : High pulse frequency of 2.5Hz enables fast procedures, 4 point aiming beam system for perfect targeting, finely tuned energy dosage to optimize performance and increase safety, focus shift for precise and automatic focusing.


...............................................................................................................


Click to view enlarge
Carl Zeiss Fundus camera 450+

Purpose :
Digital Fundus imaging

Specification : Field angle 50o,30o,20o, magnification 11x 19x 30x, resolution 6 mega pixels, high resolution digital sensors and Zeiss Optics. VISUPAC acquire software provides convenient visualization, image data integrity, unlimited Archival on MOD disk, arachive management system. Meets stringent requirements for patient's safety. (IEC 601).  Unlimited search criteria, image processing, DICOM conformance for advanced export capability. Digital imaging system for archiving encashment display and networking.


...............................................................................................................


Click to view enlarge
Humphrey Field analyzer HFA II750i with SITA


Purpose :
Measurement of Field of vision in glaucoma patients


Specification : World Wide Standard in automated perimetry, multiple testing features, data analysis software including GPA software, Touch screen display, SWAP testing, automatic fixation monitoring, automatic calibration, user friendly data storage facility using alphanumeric touch screen.


...............................................................................................................


Click to view enlarge
OTI Scan 1000 3D/B/A-scan

Purpose :
Ultrasonic imaging of the eye & orbit

Specification : Real time dynamic recording, integrated 3D,Auto topography/volume measurement, 12.5MHz B-Scan & 13MHz A-Scan high frequency UBM option, integrated B/A/3D probe, scan rate: 50 frames/second, portable & compact.


...............................................................................................................


Click to view enlarge
Canon Auto Refracto kerato meter

Purpose :
Automated objective refraction

Specification : Fully automatic, Multiple functions (kerotometry/CLBC/peripheral kerotometry) Fast and accurate estimation of refraction in spherical, cylindrical axis and cylindrical power, PD measurement. LCD colour monitor, thermal printer.


...............................................................................................................


Click to view enlarge
CSO Slit Lamp Digital Imaging System

Purpose :
Live Display of images

Specification : SL 990 video System, Images filmed by telecamera and real time acquisition of unlimited sequence image measuring, editing and image printing



 
Nursing
Site map Site map












 

 





 

 












 

 



 

 

 

 

 



 

 












 

 



 

 

 

 

 



 

 












 

 



 

 

 

 

 



 

 

Equipment Purpose Specification

Bausch & Lomb Orbscan/aberrometer
Zyoptix work station

Anterior and posterior corneal surface evaluation with corneal thickness measurement.
Evaluation of higher order aberration

Orbscan IIz provides complete analysis of the anterior segment of the eye including topography, elevation (anterior and posterior cornea) and pachymetry at 9000 data points Zywave using the single path Hartman-shack principle of aberrometry is the best wave front analyzer which quantifies the higher order aberrations of the eye Data from both orbscan and zywave is compiled and transferred to the laser via a zycard.

Zyoptics XP microkeratome

For creating thin corneal flap before lasik

Variations in flap thickness is minimized allows a thinner flap of 120 & 140 microns More corneal tissue available for correction Zero compression head to minimize flap complications .Smoother corneal beds provides better overall measured flap parameters.

Carl Zeiss operating microscope OPMI1 FR

Anterior & posterior segment Micro surgery

Crisp and crystal clear image with superior contrast, integrated 5-step magnification, motorised focusing and fiber optic illumination, retinal protection device against excessive irradiation.

Carl Zeiss operating microscope OPMI1 FR X-Y

Anterior & posterior segment Micro surgery

All above features, Motorized XY coupling guarantees reliable, exact positioning of the microscope, personalized settings for zoom focus & XY motion.

L&T Compact anesthesia machine

Administration of General Anesthesia

Oxygen pressure operated pneumatic N2O cut off system, Audio alarm for indicating oxygen failure, oxygen storing reservoir, and lever operated anti-hypoxic device.

L&T EV-500 anesthesia ventilator

Anesthesia Ventilation

Venturi principle, PEEP and CPAP modes, audio and visual alarms, LED & analogue displays, 6 hour battery back up.

AMO Sovereign compact phaco system

Suture less micro incision Cataract surgery

Closed fluidic system prevents crossed contamination, advanced digital fluidics ensures excellent chamber stability, programmable occlusion mode phaco virtually eliminates surges even at high vacuum settings, simplified programming and user friendly interface.

AMO Sovereign phaco system with white star

Suture less micro incision Cataract surgery

Cold phaco through sonolase energy, make Bi-manual phaco possible, Advanced fluidics controlled by 7 micro processors, can store upto 29 different sets of surgeon parameters.

Iridex Red laser Oculight SL, solid state Red Laser

Photocoagulation for various retinal diseases including diabetic retinopathy, trans pupillary thermo therapy for ARMD, cyclo photo coagulation in glaucoma

810nm Infra red laser, large spot slit lamp adapter for TTT, G-probe for cyclo photocoagulation, operating microscope adapter for endo photocoagulation, portable & compact design.

BPL Defibrillator DF 2509R

Cardio version in cardiac arrhythmias

Instant charging to 360J, LCD display of actual delivered energy, 100 charge/discharge cycles with fully charged batteries, visual & audio alerts, inbuilt printer, self calibration facility, portable.

BPL ECG

Recording electrocardiogram

Portable, dual power supply, automatic & manual mode recording, multi channel, thermal array recorder.

BPL pulseoximeter

Monitoring pulse & SpO2

Portable, LCD display, Graphical wave form display, real time plethysmograph display, built in rechargeable battery.

BPL Bed side monitor

Monitoring ECG & heart rate

Portable, LCD display of real time ECG and heart rate, two channels, built in rechargeable battery, protected against defibrillator shocks, good visibility, and standard frequency response.

BPL Aegis Multiparameter monitor

Monitoring vital parameters such as ECG, SpO2& NIBP

Colour TFT display, application from neonate to adult, built in rechargeable battery, 200 set vital sign data storage and recall.

Wipro GE Genius 60 Mobile X-Ray system

X-ray Imaging

60mA portable, Digital display of parameters, independent kvp & ma & timer techniques, automatic tube overload protection, audio buzzer for exposure monitoring.

CPC Stat fax semi auto analyser

Analyzing blood, urine, etc

Stat fax 2000 contains a 3+°C incubation block. With 12 stations .It is a bichromatic photometer system with a filter.

Topcon Slit lamps SL-1E & SL-3C

Anterior segment evaluation

High resolution optical head, 10x and 16x magnification brilliant illumination (SL 1E halogen illumination, SL 3C tungsten illumination). High resolution optical head, 10x, 16x magnification.

Sonomed A scan

To measure the axial length of the eye ball (for IOL power calculation)

Multiple examination modes, built in calibration cylinder, direct alphanumeric data entry, measurement review.

Tomey Auto Lensometer

Measurement of spectacle and contact lens, UV transmittance, PD, prism

High power -/+80D lens checking facility including progressive, refractive index calculation, 5.7-inch color touch panel operation display. Large data storage, built in printer.

CSO Chart projectorC.P.3000

Vision testing

Vision acuity testing at high & low contrast, contrast sensitivity testing, multiple specification charts(37 tests) with remote control.

Keratometer

To measure the curvature of anterior corneal surface

Achromatic lenses, precision objectives.02 mm accuracy. Duel eye level sighting system. Two way adjustable head and chinrest easy fixation with cross target


Baliwalla & Homi Synoptophore

Orthoptic diagnosis & treatment

Auto flashing, after image test, 2 Haidinger brushes, 14 pairs of slides

Keeler Pulsair Easy Eye

Non contact pneumatic Tonometry to measure Intra ocular pressure in glaucoma

Hand held, portable & non contact, can be used in patients with mobility difficulty, children, no pain or discomfort, accuracy within +/- 1mmHg of Goldmann

CSSD EQUIPMENTS

PCI semi automatic ETO gas sterilizer

Instrument Sterilization

2cubic feet chamber capacity, temperature alarm, calibrated humidifier, inbuilt aeration facility, built in cartridge puncturing

Nat steel Steam sterilizer

Steam Sterilization

Horizontal double door heavy duty steam sterilizer

Nat steel High speed sterilizer

Steam Sterilization

High speed autoclave completed within 30 minutes, fast & reliable, useful for large surgical loads

Nat steel  Ultrasonic cleaner

Cleaning of delicate instruments

Instruments cleaning by ultrasonic vibration, avoids damage to delicate instruments



MINOR EQUIPMENTS
Equipment Purpose Specification

WelchAllyn Ophthalmo scope direct


Examination of fundus of eye


Coaxial optical system, halogen illumination, wall mounted transformer.


WelchAllyn Ophthalmo scope indirect

Examination of fundus of eye

Excellent convergence control, Halogen light source, soft tilt park, Ergnomically Designed controls.

Heine Ophthalmo scope direct

Examination of fundus of eye

Coaxial optical system halogen illumination, wall mounted transformer.

Heine Ophthalmo scope indirect

Examination of fundus of eye

Sharp stereoscopic images, small pupil aperture, halogen illumination, sturdy design .

Heine retino scope

Manual objective refraction

Coaxial optical system halogen illumination, wall mounted transformer.

WelchAllyn Retinoscope

Manual objective refraction

Coaxial optical system halogen illumination, wall mounted transformer.

Haag streit Applanation Tonometer Goldman

Measuring IOP

Applanation tonometry, most accurate method to record IOP, gold standard.

Video Indirect ophthalmoscope

Fundus Examination & teaching purpose

High resolution CCD colour camera with advanced digital signal processing. Fine focusing adjustment to get sharp video images. Wide visual field and strain free binocular vision. Connection to video peripherals such as VCR, TV, etc. Binocular Indirect ophthalmoscope (BIO). Video focusing distance: 140mm-2000mm.video out put: PAL.


 
Home Events Community eye  care Press room FAQ Career @ ahalia Treatments Contact us Enquiry About ahalia group Eye departments